Description
Axia V1500A Touch Screen Features
The Axia V1500A monitor is designed for a fast paced work environment with an intuitive touch screen. The patient information along with vital sign settings can be quickly modified to meet the needs of a patient’s changing condition. Its upgradable design fits-in and moves amongst many patient care areas. Offers ECG with arrhythmia detection, standard measurements of: non-invasive blood pressure, motion tolerant SpO2, temperature, respira- tion rate and capnography.
The Axia V1500A monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a based hospital information system.
- Optional: integrated Dräger 5-Agent Anesthesia Gas Bench with CO2 capabilities
- High resolution 15 inch touch-screen display
- Capnography with EtCO2 monitoring (optional)
- Auto setting of alarm limits
- Color-coded alarms
- Graphical and tabular trends (72 hours)
- Patient data entry
- OxiCRG, drug dose calculation
- Trace: 8 wave forms
- Trend Time: 1 – 72 Hours
- Networking capability (wireless and non-wireless)
- Color of the waveforms can be changed
- Battery backup (removable batteries)
- Weight: 10.85 lbs.
- Applications: Neonatal, pediatric and adult patients
Axia V1500A Touch Screen Specifications
General Specifications
- Display: 12.1 inch color touch screen
- Trace: 8 waveforms
- Indicator: Alarm indicator, Power indicator, QRS beep and alarm sound
- Trend time: 1 – 72 hour, Recorder: Built-in, thermal array, 3 channels Record width: 48mm, Recorder paper: 50mm, Record speed: 25mm/s, 50mm/s
Networking
- Industry standard 802.11b/g wireless network
Power
- Source: External AC power or internal battery
- AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
- Battery: Built-in & rechargeable lithium ion
- Operating Time: 3+ hours
Environmental Specifications
- Temperature: Operating: 5 ~ 40 °C Storage: -20 ~ 65 °C
- Humidity range: Operating: ≤80 % Storage: ≤80 %
ECG
- Input: 5-lead ECG cable and standard AAMI line for connection
- Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
- Gain Choice : x0.5, x1, x2, x4
- Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
- ECG Waveforms: 7 channels
- Penetration Voltage:4000VAC 50/60Hz
- Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
- HR Display Range: 30 ~ 300bpm
- Accuracy: ±1bpm or ±1%, whichever is greater
- Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm
RESP
- Measure Method: RA-LL impedance
- Range: 0 ~ 120 rpm
- Accuracy: ±3 rpm
- Alarm Limit Setting:upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm
- Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
Sp02
- ASpO2: Anti-motion SpO2
- SpO2% Range: 0-100%
- SpO2 Accuracy: ±2% (70 ~ 100%, non-motion) ±3% (70 ~ 100%, motion)
- Pulse Rate Range: 30-250 bpm
- Pulse Rate Accuracy: ±2 bpm (non-motion, ±3 bpm (motion)
- Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100%
- SpO2 Probe: Red light LED wavelength 660nm±5nm, Infrared light LED wavelength 940nm±10nm
NIBP
- Measuring Technology: automatic oscillating measurement
- Cuff Inflating: <30s (0 ~ 300 mmHg, standard adult cuff)
- Measuring Period: AVE<40s
- Mode: Manual, Auto
- Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
- Pulse Rate Range: 30 ~ 250 (bpm)
- Adult/Pediatric Mode: SYS: 40 ~ 250 (mmHg), DIA :15 ~ 200 (mmHg)
- Neonatal Mode: SYS: 40 ~ 135 (mmHg), DIA : 15 ~ 100 (mmHg)
- Maximum Mean error: ±5mmHg
- Maximum Standard deviation: 8mmHg
- Resolution: 1mmHg
- Overpressure Protection: Adult Mode: 300 (mmHg)
- Neonatal Mode: 160 (mmHg)
- Alarm Limit Setting: SYS: 50 ~ 240 mmHg
- DIA: 15 ~ 180 mmHg