Axia i120

Axia i120

Description

Axia i120 Features

The Axia i120 is an adult, pediatric, and neonatal patient monitor. The i120 has a 12.1-inch high-resolution touchscreen display and can measure 3 and 5-lead ECG, respiration rate, Spo2, pulse rate, NIBP, and temperature. Optional upgraded are available for 2-IBP, EtCO2, Nellcor SpO2, 12-lead ECG, SunTech NIBP, Cardiac output, and Cerebral state monitoring.

  • 21.1” high-resolution touchscreen display
  • Displays between 9 and 13 waveform traces
  • Customizable NIBP measure cycles
  • 3 or 5-lead ECG and optional 12-lead ECG
  • Standard configuration ECG, Respiration, SpO2, PR, NIBP, and Temperature

Axia i120 Specifications

Dimensions

  • Height: 13.15 in (33.4 cm)
  • Width: 12.32 in (31.3 cm)
  • Depth: 7 in (17.8 cm)
  • Weight: 12.57 lb (5.7 kg)

Display

  • Type: TFT Color Touchscreen
  • Size: 12.1 in (13.73 cm)

ECG

  • Input Dynamic Range: ±(0.5mVp~5mVp)
  • Differential Input Impedance: ≥10MΩ
  • Bandwidth: 0.05~150Hz (Dignostic); 0.5~40Hz (Monitoring); 1~20Hz (Operation)
  • CMRR: ≥90dB (Diagnostic); ≥105dB (Monitoring & Operation)
  • Sensitivity Selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
  • Sweeping Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
  • HR Measuring Range: 15~350bpm
  • HR Accuracy: ±1% or ±2bpm, whichever is greater

Respiration Rate

  • Measuring Range: 0~120rpm
  • Measuring Accuracy: ±5% or ±2 rpm, whichever is greater

NIBP

  • Type: Oscillometric
  • Typical Measurement Time: <30 seconds (adult cuff)
  • NIBP measuring accuracy: Mean difference: ±5mmHg; Standard Deviation: 8mmHg
  • NIBP Measurement Mode: Manual, Auto, STAT, Multi-cycle mode
  • Auto Measuring Intervals: 1-480min
  • NIBP measuring range
    • SYS: 40~275mmHg (Adult); 40~200mmHg (Pediatric); 40~135mmHg (Neonate)
    • DIA: 10~210mmHg (Adult); 10~150mmHg (Pediatric); 10~95mmHg (Neonate)
    • MAP: 20~230mmHg (Adult); 20~165mmHg (Pediatric); 20~110mmHg (Neonate)

SpO2

  • Type: Dual-wavelength optical
  • Range: 0%~100%
  • Accuracy: Arms is not greater than 2% for SpO2 range 70~100%.
  • PR Range: 30~250bpm
  • PR Accuracy: ±2bpm or ±2%, whichever is greater
  • Low Perfusion Performance: As low as 0.3%.

Temperature

  • Compliant: ISO 80601-2-56: 2017
  • Range: 32-122°F (0-50°C)
  • System Response Time: <150s
  • Alarm Accuracy: ±0.1°C
  • Accuracy
    • Without Probe: In the range of 32-122°F (0-50°C), error is ±0.1 °C
    • With Probe: In the range of 77-113°F (25-45°C), error is ±0.2°C
    • In other ranges, error is ±0.4°C

Cerebral State Monitoring (CSM) (Optional)

  • EEG sensitivity: ±400μV
  • Noise Level: <2μVp-p, <0.4μV rms (1~250Hz)
  • CMRR: >140dB
  • Input impedance: >50Mohm
  • CSI and Update: 0-100. filter: 6-42Hz, 1 sec. update
  • EMG%: 0-100 (logarithmic), filter: 75-85 Hz, 1 sec. update
  • BS%: 0-100. filter: 2-42 Hz, 1 sec. update

IBP (Optional)

  • Type: Strain gauge transducer
  • Input Sensitivity: 5μV/V/mmHg
  • Measuring Range: -50~300mmHg
  • Measuring Accuracy: ±2% or ±4mmHg, whichever is greater
  • Measuring Positions: ART, RAP, PA, LAP, CVP; ICP, AUXP1, AUXP2
  • Calibration: None

Cardiac Output (C.O.) (Optional)

  • Blood temperature Range: 73-109°F (23-43℃); accuracy: ±0.9°F (±0.5℃)
  • Injecta Temperature Range: 32-68°F (0-20℃), accuracy: ±0.9°F (±0.5℃)
  • Measuring Range: 0.2~20 L/min
  • Measuring Accuracy: ±0.2 L/min or ±10%, whichever is greater

EtCO2 (Optional)

  • Type: Sidestream / Mainstream
  • Range: 0-150 mmHg
  • Sampling Rate (Sidestream): 50 ml/min fixed flow rate
  • Response Time / Rise Time
    • Sidestream
      • Response time <9s
      • Rise Time: <60ms
  • Warm-up Time
    • Mainstream: Parameters can be displayed within 15s
    • Sidestream: Parameters can be displayed within 20s